NXA Series the All-In-One Noise Test System

Why the NXA Series ?

  • RF and Microwave Devices from few MHz to 6, 26 and 50 GHz
  • Cross-Correlation technique
  • Reference sources built-in
  • Single button fast measurement
  • Residual/Additive Phase Noise Measurements capable
  • CW or pulsed signals compatible
  • Ideal for production factory

Ask a question about this product

Description

Description

The NXA is a fully automated Phase Noise analyzer. Its dual channel architecture allows the system to use a cross-correlation process to cancel its internal noise floor. This reliable technique provides access to the unique noise floor performance of the DCNTS.

A completely new user interface based on a large 14 inch touchscreen simplifies the operation, focusing the user on the measurement result itself and not on the measurement technique. Experts can always access advanced settings if needed.

Quick and easy phase noise plots can be obtained without any training so the NXA Series can be operated by any manufacturing technician. This is the only instrument that combines great ease of use and state of the art performance.

With its internal frequency references, measurements are made extremely easy without the hassle of connecting cables and tweaking settings. However, when ultimate performance is required, the capability to use external reference sources like crystal oscillators, SAWs or SLCOs pushes the instrument noise floor down to the thermal noise.

Specifications

NXA-6 Specifications

Input Frequency Measurement Range: 5 MHz to 6 GHz (using external ref. sources); 80 MHz to 6 GHz (using internal ref. sources)
Offset analysis 0.01 Hz to 40 MHz
Cross Correlation Cuts Phase Noise 1 to 100,000
Accuracy 1 k - 1 MHz offset: +/- 2 dB
Accuracy 1 M - 40 MHz offset: +/- 3 dB (*optional)

For more specification please download .Pdf datasheet

NXA-26 Specifications

Input Frequency Measurement Range: 5 MHz to 26.5 GHz (using external ref. sources); 80 MHz to 26 GHz (using internal ref. sources)
Offset analysis 0.01 Hz to 40 MHz
Cross Correlation Cuts Phase Noise 1 to 100,000
Accuracy 1 k - 1 MHz offset: +/- 2 dB
Accuracy 1 M - 40 MHz offset: +/- 3 dB (*optional)

For more specification please download .Pdf datasheet

NXA-50 Specifications

Input Frequency Measurement Range: 5 MHz to 50 GHz (using external ref. sources); 80 MHz to 26.5 GHz (using internal ref. sources)
Offset analysis 0.01 Hz to 40 MHz
Cross Correlation Cuts Phase Noise 1 to 100,000
Accuracy 1 k - 1 MHz offset: +/- 2 dB
Accuracy 1 M - 40 MHz offset: +/- 3 dB (*optional)

For more specification please download .Pdf datasheet

Options

Main Options list

  • Amplitude Noise detector allows Amplitude noise measurements.
  • Pulsed signals compatibility to measure gated CW type signals.

Many other options available as standard. We also offer custom modules to suit your application.


Document Library

File Description Document Type Size File Name
NXA-6 Short Form Datasheet Datasheet PDF 374 Ko NoiseXT_NXA-6.pdf
NXA-26 Short Form Datasheet Datasheet PDF 313 Ko NoiseXT_NXA-26.pdf
NXA-50 Short Form Datasheet Datasheet PDF 289 Ko NoiseXT_NXA-50.pdf

JOIN OUR MAILING LIST

AUTOMATIC TRANSLATES